Flame arrestors are safety devices for reliable protection against hazardous flame flash-back in gas supply systems.
The F53N-ES and F53N/H-ES Series safety devices provide protection against flame flash-back and extinguish flame blow-backs in gas supply systems. They are employed in gas supply systems with corrosive gases, such as fuel gas or oxygen, in the chemical industry, in the laboratory sector or in process technology. The devices can be installed in any position. The ambient temperature must not exceed 70°C.
The F53N-ES and F53N/H-ES Series safety devices are designed without check valve for minimum working pressures upline and downline of analysis devices.
F53N-ES and F53N/H-ES Series safety devices extinguish hazardous flame flash-backs by means of flame arrestors (FA) of sintered chrome-nickel steel. The temperature-controlled cut-off valve (TV) extinguishes flame blow-backs.
Safety elements: | Flame arrestor (FA) Temperature-controlled cut-off valve (TV) |
Gas types: | Max. working pressure [bar] |
Acetylene (A) | 1.5 |
Natural gas (M) | 5.0 or 12.0 (F53N/H) |
Liquid gas (P) | 5.0 or 8.0 (F53N/H) |
Hydrogen (H) | 3.0 or 10.0 (F53N/H) |
Ethylene (E) | 9.0 (F53N/H) |
Oxygen (O) | 30.0 |
Compressed air (D) | 30.0 |
Material: | |
Housing: | Stainless steel |
Flame arrestor: | Stainless steel |
Seals: | Elastomers |
Connection: | 1/4 inch NPT female, other connections on demand |
Wir helfen Ihnen gerne
Alle mit * gekennzeichneten Felder sind Pflichtfelder.
The RF53N-ES and RF53N/H-ES Series safety devices provide protection against flame flash-back and gas back-flow, and extinguish flame blow-backs in gas supply systems. They are employed in gas supply systems with corrosive gases in the chemical industry, in the laboratory sector or in process technology. The devices can be installed in any position. The ambient temperature must not exceed 70°C.
RF53N-ES and RF53N/H-ES Series safety devices extinguish hazardous flame flash-backs by means of flame arrestors (FA) of sintered chrome-nickel steel. The temperature-controlled cut-off valve (TV) extinguishes flame blow-backs. In addition, the formation of potentially explosive mixtures in the gas supply is prevented by gas non-return valves (NV). The RF53N-ES and RF53N/H-ES Series with filter in the gas inlet offers protection against contamination from the gas supply during long service lives.
Safety elements: | Flame arrestor (FA) Temperature-controlled cut-off valve (TV) Non-return valve (NV) |
Gas types: | Max. working pressure [bar] |
Acetylene (A) | 1.5 |
Natural gas (M) | 5.0 or 12.0 (RF53N/H-ES without BAM certification) |
Liquid gas (P) | 5.0 or 8.0 (RF53N/H-ES) |
Hydrogen (H) | 3.0 or 9.0 (RF53N/H-ES) |
Ethylene (E) | 12.0 (RF53N/H-ES) |
Oxygen (O) | 30.0 |
Compressed air (D) | 30.0 |
Material: | |
Housing: | Stainless steel |
Flame arrestor: | Stainless steel |
Seals: | Elastomers |
Connection: | 1/4” or 3/8” NPT female, other connections on demand |
Wir helfen Ihnen gerne
Alle mit * gekennzeichneten Felder sind Pflichtfelder.
The F85-10N-ES and F85-10N/H-ES Series safety devices provide protection against flame flash-back and extinguish flame blow-backs in gas supply systems. They are employed in gas supply systems with corrosive gases, such as fuel gas or oxygen, in the chemical industry, in the laboratory sector or in process technology. The devices can be installed in any position. The ambient temperature must not exceed 70°C.
The F85-10N-ES Series safety devices are designed without check valve for minimum working pressures upline and downline of analysis devices.
F85-10N-ES and F85-10N/H-ES Series safety devices extinguish hazardous flame flash-backs by means of flame arrestors (FA) of sintered chrome-nickel steel. The temperature-controlled cut-off valve (TV) extinguishes flame blow-backs.
Safety elements: | Flame arrestor (FA) Temperature-controlled cut-off valve (TV) |
Gas types: | Max. working pressure [bar] |
Acetylene (A) | 1.5 |
Natural gas (M) | 5.0 or 10.0 (F85-10N/H-ES) |
Liquid gas (P) | 5.0 or 5.0 (F85-10N/H-ES) |
Hydrogen (H) | 4.0 or 10.0 (F85-10N/H-ES) |
Ethylene (E) | 5.0 (without BAM certification) or 5.0 (F85-10N/H-ES) |
Oxygen (O) | 30.0 |
Compressed air (D) | 30.0 |
Material: | |
Housing: | Stainless steel |
Flame arrestor: | Stainless steel |
Seals: | Elastomers |
Connection: | 1/4” or 3/8” NPT female, other connections on demand |
Wir helfen Ihnen gerne
Alle mit * gekennzeichneten Felder sind Pflichtfelder.
The RF85-10N-ES and RF85-10N/H-ES Series safety devices provide protection against flame flash-back and gas back-flow, and extinguish flame blow-backs in gas supply systems. They are employed in gas supply systems with corrosive gases, such as fuel gas or oxygen, in the chemical industry, in the laboratory sector or in process technology. The devices can be installed in any position. The ambient temperature must not exceed 70°C.
RF85-10N-ES and RF85-10N/H-ES Series safety devices extinguish hazardous flame flash-backs by means of flame arrestors (FA) of sintered chrome-nickel steel. The temperature-controlled cut-off valve (TV) extinguishes flame blow-backs. In addition, the formation of potentially explosive mixtures in the gas supply is prevented by gas non-return valves (NV).
Safety elements: | Flame arrestor (FA) Non-return valve (NV) Temperature-controlled cut-off valve (TV) |
Gas types: | Max. working pressure [bar] |
Acetylene (A) | 1.5 |
Natural gas (M) | 5.0 or 10.0 (RF85-10N/H-ES) |
Liquid gas (P) | 5.0 or 5.0 (F85-10N/H-ES) |
Hydrogen (H) | 4.0 or 10.0 (F85-10N/H-ES) |
Ethylene (E) | 5.0 (without BAM certification) or 5.0 (F85-10N/H-ES) |
Oxygen (O) | 30.0 |
Compressed air (D) | 30.0 |
Material: | |
Housing: | Stainless steel |
Flame arrestor: | Stainless steel |
Seals: | Elastomers |
Connection: | 1/4” or 3/8” NPT female 9/16”-18UNF or 7/8”-14UNF VCR other connections on demand |
Wir helfen Ihnen gerne
Alle mit * gekennzeichneten Felder sind Pflichtfelder.
F100N-ES Series safety devices are employed in gas supply systems in the chemical industry or process technology. The devices can be installed in any position. The ambient temperature must not exceed 70°C. F100N-ES Series safety devices provide protection against flame flash-back and extinguish flame blow-backs for hydrogen up to 17 bar, e.g. during flame spraying.
F100N-ES Series safety devices extinguish hazardous flame flash-backs by means of flame arrestors (FA) of sintered chrome-nickel steel. The temperature-controlled cut-off valve (TV) extinguishes flame blow-backs.
Safety elements: | Flame arrestor (FA) Temperature-controlled cut-off valve (TV) |
Gas types: | Max. working pressure [bar] |
Hydrogen (H) | 17.0 |
Material: | |
Housing: | Stainless steel |
Flame arrestor: | Stainless steel |
Seals: | Elastomers |
Connection: | 1/2” NPT female |
Wir helfen Ihnen gerne
Alle mit * gekennzeichneten Felder sind Pflichtfelder.
+49 4207 6994-0
+49 4207 6994-40